Heating&cooling time has been reduced by 60 to 75%(compared toourconventional products) and a silicon free type ovenforproductionlines that support multi power sources is addedtotheline-up.
-
Time for heating and coolingoftheproduct has been improved by 50% or more comparedtoourconventional products and the objective is toreduceproductiontakt time.
-
Time for attainingthehighesttemperature has been reduced by up to 1/3 (at noload,compared toour conventional products) and time fordecreasingtemperature inthe bath, by 50% (at no load, compared toourconventionalproducts). Work efficiency can begreatlyimproved.
-
The damper willautomaticallyopenwhen operation finishes, which requires notroublesomemanualoperation. Also, the optional 10-step variable fancontrolfunctionallows you to set to any wind amount youwant.
-
A silicon-free eco oven withitsdoorpacking of Viton® fluoroelastomer. (DNG610V/810V)
-
This product supportsmultipowersources. It can be operated simply by connecting to 200to240Vpower source.
-
Four-foldoverheatpreventivefunctions (automatic overheat prevention, heaterroomoverheatprevention, overheat prevention in the bath,andtemperature fuse)assure the optimal safety. The productalsofacilitates the selfdiagnostic function, the alarmhistorymonitoring function, the keylock function and anover-currentelectric leakage breaker.
-
Abundantfunctions(externalcommunication that supports RS485/FORWARD,external alarm,time-up,output on the logger) allow upgrading of thesystemaccording tothe specific application.
Specifications
|
Productcode
|
212864
|
212866
|
212865
|
212867
|
Model
|
DNG610
|
DNG610V
|
DNG810
|
DNG810V
|
System
|
Forced convection
|
Performance*1
|
Operatingtemp.range
|
Roomtemp. +10 deg.C to 300 deg.C
|
Temp.adjustmentaccuracy
|
+/-0.3deg.C (at 300 deg.C)
|
Temp.distributionaccuracy
|
+/-3.0deg.C (at 300 deg.C)
|
Time toattainmax.temp.
|
55min.orless from 25 deg.C to 300 deg.C
|
50min.orless from 25 deg.C to 300 deg.C
|
Time toattainmin.temp.
|
55min.orless from 25 deg.C to 300 deg.C
|
Approx.40 min. or less from 300 deg.C to 50 deg.C
|
Configuration
|
Interior/externalmaterial
|
Stainless steel plate/electrogalvanizedsteel(epoxy/melaminecoated)
|
Heater/heatinsulator
|
SUSpipeheater, glass wool
|
Heatercapacity
|
200to240V 4 to 5.8 kW
|
200to240V 5.4 to 7.8 kW
|
Fan
|
Siroccofan x 2
|
Fan motor
|
Condenser 30W x 2
|
30Wx2
|
Sourcevoltageswitching
|
Withthemulti power source selector switch on the rearpanel
|
Cable port
|
Oneportat the right side: I.D. 30 mm
|
Doorpacking
|
Siliconrubber
|
Viton®fluoroelastomer
|
Siliconrubber
|
Viton®fluoroelastomer
|
Airsupplyport
|
I.D.100mm: on top of the main unit
(opened/closed with an electric damper, with amanualcontrolknob)
|
Exhaustport
|
I.D.100mm: on top of the main unit
(opened/closed with an electric damper, with amanualcontrolknob)
|
Heatercontrol
|
SSRcontrol
|
Sensor
|
K-thermocouple (in the bath and heater kiln)
|
Functions
|
Safetyfunctions
|
Selfdiagnosticfunction(temp. sensor error, heater disconnection,SSRshort-circuit,automatic overheat prevention, and otherfunctionsof CR5), keylock, program lock, independent overheatprotectionwithin the bath,independent heater overheatprevention,over-current electricleakage breaker, temp. fuse
|
Otherfunctions
|
Standardfunctions:RS485external communication (supports FORWARD), externalalarm,time-up,and output on the logger
|
Standards
|
Powersupply
|
Singlephase: AC200 to 240V, 21 to 25A
|
Singlephase: AC200 to 240V, 28 to 33.5A
|
Internalcapacity
|
180L
|
360L
|
Externaldimensions*2
|
770x876x 1,455 mm (W x D x H)
|
770x876x 1,780 mm (W x D x H)
|
Internaldimensions
|
600x600x 500 mm (W x D x H)
|
600x600x 1,000 mm (W x D x H)
|
Equipmentweight
|
Approx.145 kg
|
Approx.160 kg
|
Numberofshelves
|
Stainless steel wire x 2
|
Stainless steel wire x 4
|
Shelfloading
|
Approx.30 kg/each
|
Numberofshelfsteps/shelf pitch
|
12steps/30 mm
|
28steps/30mm
|
*1Conditions: temperature and humidity: 23deg.C+/-5deg.C,65%RH+/-20% (no load)
*2 External dimensions donotincludeprotrusions.
|
Control panel CR5
|
|
Majorfunctions
|
Operation modes
1. Fixed operation
2. Fixed auto stop operation
3. Fixed quick auto stop operation
4. Fixed auto start operation
5. Program operation
6. Program auto start operation
|
Useful functions
Wind amount adjustment function (10 steps)
Automatic open/close damper function
Display switching during operation
Heater output operation amount display
Program name setting
Operation guide function, etc.
|
|
Temp. rise curve (AC 200V at 23 deg.C)
|
Temp. decrease curve (during automatic exhaust/air supply at 23 deg.C)
|
|
|
Comparison oftemperature rise/decrease timewithconventionalproducts
|
Comparisonof DNG610 and conventional products/ DNG810andconventionalproducts
Time required for rise to decrease has been reducedtoapprox.1/3.
23 deg.C (normal temp.) to 200 deg.C to 50 deg.C Required time
DNG610: 23 min for heating + 29 min for cooling = 52 min
Conventional product: 60 min for heating + 100 min for cooling=160min
|
Temp.rise time (AC200V at room temp.23deg.C)
Item name
|
DNG610
|
Conventional products
|
DNG810
|
Conventional products
|
300deg.C
|
50
|
-
|
44
|
-
|
250deg.C
|
33
|
140
|
30
|
-
|
200deg.C
|
23
|
60
|
22
|
47
|
23deg.C (Normal temp.)
|
-
|
-
|
-
|
-
|
|
Temp.decrease time
Item name
|
DNG610
|
Conventional products
|
DNG810
|
Conventional products
|
300deg.C
|
0
|
-
|
0
|
-
|
250deg.C
|
2(0)
|
0
|
2
|
-
|
200deg.C
|
6(4)
|
12
|
6(0)
|
0
|
100deg.C
|
15(13)
|
50
|
20(14)
|
35
|
50deg.C
|
31(29)
|
100
|
37(31)
|
84
|
|
Internal bath
|
Air supply/exhaust port & manual damper
|
Multi power source selector switch
|
Cable port
|
|
|
|
|
Optional items
|
Dimensional drawing (mm)
|
Item name
|
Product code
|
RS485-232C conversion adaptor
|
281126
|
Application software FORWARD
|
281501
|
Wireshelf/shelf peg
|
211064
|
Cable port of I.D. 25 mm
|
281502
|
Cable port of I.D. 50 mm
|
281503
|
RMhybrid recorder (6 Ch)
|
281017
|
PHRvideo chart recorder (6 Ch)
|
281019
|
T-thermocouple sensor for recorder 2m
|
281554
|
T-thermocouple sensor for recorder 2m
(with calibration certificate)
|
281555
|
|
|
|